Add to Cart
High precision measurement of three phase voltage, three phase current, active power, reactive power, apparent power, power factor, frequency of electric parameters |
Forward and reverse active or reactive energy measurement |
Measurement of three-phase voltage, three-phase current total harmonic distortion (THD), 2-31 odd harmonic component |
Provide the digital tube display, local data query |
Menu button intuitive, simple operation |
Current, voltage gain programmable setting |
Programmable voltage ratio |
Support for fire control, remote cut off the fault circuit |
Provide multiple loop control nodes, can be used for the alarm, trip control |
Support for RS-485 communication, Modubus-RTU protocol |
Support for switching input, output, analog quantity transmitting output |
Convenient installation, wiring is simple, small engineering quantity |
A wide range of AC/DC power supply: AC/DC 80-270V |
To be completed by SCADA, PLC in a variety of communications software network |
Accuracy of measurement | Voltage level 0.5, current level 0.5, active power 0.5, reactive power level 0.5,Frequency ±0.02Hz, active electric energy class 0.5s or class 0.2s, reactive energy grade 1 or grade 2, power factor 0.5 |
Signal input | Connection mode of four phase three wire, three phase three line |
Rated voltage of AC 57.7V, AC 100V, AC 220V, AC 380V | |
Over load 1.2 times ( Continued ), 2 times / second ( instantaneous ) | |
Power <1VA/ phase | |
Impedance >300KΩ, current: <20mΩ | |
The frequency of 45~65Hz | |
Auxiliary power supply | Working range of AC/DC 80V~270V |
Power consumption: <4VA | |
Function module | Communication interface 1 way RS-485 communication, Modbus-RTU protocol |
Baud rate: 1200~9600bps, the default 2400bps | |
Switch input support 4 stem node input | |
The switch output support 3 relay output, capacity: AC 250V/5A, DC 30V/5A | |
Transmission output support 3 analog output: 0/4~20mA or 0~5/10V | |
Environment | Working temperature: -10℃~+55℃ |
Storage temperature: -25℃~+70℃ | |
Relative humidity is less than 93%, no corrosive gas | |
Elevation: ≤2500m | |
Safety | Insulation resistance: >100MΩ |
AC withstand voltage: AC 2KV | |
Electromagnetic compatibility | ESD level: 4 |
Electrical fast transient burst level: 4 |
Intelligent Digital Panel Meter with A V Hz Cos W Var Kwh Varh(9999 display)
Model No. | Display | Frame size (mm) | Hole size (mm) |
RH-3D2Y | LCD | 120*120 | 111*111 |
RH-3FD2Y | LCD | 120*120 | 111*111 |
RH-3HD2Y | LCD | 120*120 | 111*111 |
RH-3FHD2Y | LCD | 120*120 | 111*111 |
RH-3D3Y | LCD | 96*96 | 92*92 |
RH-3FD3Y | LCD | 96*96 | 92*92 |
RH-3HD3Y | LCD | 96*96 | 92*92 |
RH-3FHD3Y | LCD | 96*96 | 92*92 |
RH-3D7Y | LCD | 96*96 | 76*76 |
RH-3D6Y | LCD | 96*96 | 68*68 |
Extended Modules:
AC/DC power supply (switching power supply) $4
AO: $7 more for each stem node
DI: $4 more for each stem node
DO: $4 more for each stem node
“*” means unconventional products of our corporation